IPACK

Project ImagePhoto produit

<heading-style-h2>IPACK<heading-style-h2>

<heading-style-h6>Intermediate anchor: one matrix, four plates depending on the support.<heading-style-h6>

The IPACK holds the 12 mm lifeline cable in an MAC I aluminium matrix, clamped by 4 M10 bolts tightened to 50 Nm. Only the stainless steel plate changes to suit the support: rock bolt, open rung, Raumer bar or tree.

All four versions offer the same strength: working load 20 kN, breaking load 40 kN. Their weight ranges from 0.41 to 0.51 kg.

<heading-style-h3>IPACK 80 — on rock bolt<heading-style-h3>

INOX 80 plate

INOX 80 plate. To create intermediate points directly in the rock. Weight: 0.51 kg.

Installation
1. Check the condition of the anchor support and the cable.
2. Install a 12 or 14 mm stainless steel rock bolt, 125 to 180 mm long, in sound rock. Chemical anchoring may be needed if the rock quality is not satisfactory.
3. Position the 12 mm cable inside the aluminium matrix using the 4 M10 bolts, then tighten to 50 Nm.

<heading-style-h3>IPACK 4 80 — on open rung<heading-style-h3>

INOX 4 80 plate

INOX 4 80 plate. For installation on any type of open rung. A spacer is available for some rung models. Weight: 0.50 kg.

Installation
1. Check the condition of the anchor support and the cable.
2. Fit 2 A4 stainless steel bolts with Nylstop nuts on the open rung. Depending on the rung model, fit a 6 mm stainless steel mounting spacer so that the rope can pass between the IPACK and the rung.
3. Position the 12 mm cable inside the aluminium matrix using the 4 M10 bolts, then tighten to 50 Nm.

<heading-style-h3>IPACK SINGLE — on Raumer bar<heading-style-h3>

INOX SINGLE plate

INOX SINGLE plate. For equipping intermediate points on a Raumer bar. Weight: 0.41 kg.

Installation
1. Check the condition of the anchor support and the cable.
2. Fit 2 A4 stainless steel bolts on the Raumer bar.
3. Position the 12 mm cable inside the aluminium matrix using the 4 M10 bolts, then tighten to 50 Nm.

<heading-style-h3>IPACK SANGLES — on tree<heading-style-h3>

INOX SANGLE plate

INOX SANGLE plate. To control the cable between two plates in natural settings: the IPACK keeps the cable from rubbing against the tree. Weight: 0.46 kg.

Installation
1. Check the condition of the anchor support and the cable.
2. Fit the strap on the plate and around the tree. The strap can be up to 35 mm wide.
3. Position the 12 mm cable inside the aluminium matrix using the 4 M10 bolts, then tighten to 50 Nm.

<heading-style-h3>Installation advice<heading-style-h3>

The hook must always be able to pass freely between the support and the IPACK: check that it passes after installation. Cable loops can be made to avoid direct impact between the connectors and the IPACK.
The service life of the equipment depends on the quality of the support and the environment. It may be shorter in certain environments (snow, ice, rockfall…).
A minimum inspection every 12 months is required.

USE

OUTDOOR

Matrix
MAC I
Material
316L stainless steel, aluminum matrix
Bec
System
Bolts
4 GAC 10x30 bolts
Tightening torque
50 Nm
Upper stop
Lower stop
3-piece games
Diameter
mm
Vis
Angle
°
specifications
security
Norm
EU certificate type no.
Certification body - Conformity certificate number
Long axis break
Kn
Minor axis break
Kn
Coque
Resistance
Usage load resistance (CMU)
20
Kn
Resistance to breaking load (CMR) or sliding
40
Kn
Sliding
Kn
Number of users
Breaking resistance
lb
Masse
lb
Pose
Height
mm
Fixation
Montage
Section
ask for a quote
Free movements without danger
Free movements without danger

Follow our news

Logo Hookt
By clicking on Register, you agree that Hookt processes your personal data in accordance with the legal notice and privacy policies
Thank you! Your submission has been received!